Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
PLoS One ; 17(3): e0264138, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35294956

RESUMO

FoundationOne®CDx (F1CDx) is a United States (US) Food and Drug Administration (FDA)-approved companion diagnostic test to identify patients who may benefit from treatment in accordance with the approved therapeutic product labeling for 28 drug therapies. F1CDx utilizes next-generation sequencing (NGS)-based comprehensive genomic profiling (CGP) technology to examine 324 cancer genes in solid tumors. F1CDx reports known and likely pathogenic short variants (SVs), copy number alterations (CNAs), and select rearrangements, as well as complex biomarkers including tumor mutational burden (TMB) and microsatellite instability (MSI), in addition to genomic loss of heterozygosity (gLOH) in ovarian cancer. CGP services can reduce the complexity of biomarker testing, enabling precision medicine to improve treatment decision-making and outcomes for cancer patients, but only if test results are reliable, accurate, and validated clinically and analytically to the highest standard available. The analyses presented herein demonstrate the extensive analytical and clinical validation supporting the F1CDx initial and subsequent FDA approvals to ensure high sensitivity, specificity, and reliability of the data reported. The analytical validation included several in-depth evaluations of F1CDx assay performance including limit of detection (LoD), limit of blank (LoB), precision, and orthogonal concordance for SVs (including base substitutions [SUBs] and insertions/deletions [INDELs]), CNAs (including amplifications and homozygous deletions), genomic rearrangements, and select complex biomarkers. The assay validation of >30,000 test results comprises a considerable and increasing body of evidence that supports the clinical utility of F1CDx to match patients with solid tumors to targeted therapies or immunotherapies based on their tumor's genomic alterations and biomarkers. F1CDx meets the clinical needs of providers and patients to receive guideline-based biomarker testing, helping them keep pace with a rapidly evolving field of medicine.


Assuntos
Genômica , Neoplasias , Biomarcadores Tumorais/genética , Genômica/métodos , Sequenciamento de Nucleotídeos em Larga Escala/métodos , Humanos , Mutação , Neoplasias/tratamento farmacológico , Neoplasias/genética , Neoplasias/patologia , Reprodutibilidade dos Testes
2.
J Mol Diagn ; 24(5): 543-553, 2022 05.
Artigo em Inglês | MEDLINE | ID: mdl-35301118

RESUMO

Clinical implementation of mutational analysis for next-generation sequencing-based assays has largely been of a binary nature, with pathogenic mutations being reported as either positive or negative. Actionability on the continuous output of variant allele frequency (VAF) has not been well characterized in the clinical setting, thus limiting its use. In this study, analytical validity and performance of the short variant VAF based on a next-generation sequencing-based liquid biopsy assay, FoundationOne Liquid CDx, were evaluated through assessment of precision, analytical accuracy, limit of blank, and limit of detection. Analytical validation of VAF values measured by using FoundationOne Liquid CDx supports that these values are accurate, precise, robust, and linear with the true VAF value. The association of allele frequency of clinically relevant short variants in circulating-free DNA and the association with overall survival for patients using real-world data were also assessed. The results of the association analysis indicate that VAF of the predictive biomarker mutation negatively correlates with overall survival of patients with non-small cell lung cancer.


Assuntos
Carcinoma Pulmonar de Células não Pequenas , Ácidos Nucleicos Livres , DNA Tumoral Circulante , Neoplasias Pulmonares , Biomarcadores Tumorais/genética , Carcinoma Pulmonar de Células não Pequenas/diagnóstico , Carcinoma Pulmonar de Células não Pequenas/genética , Carcinoma Pulmonar de Células não Pequenas/patologia , DNA Tumoral Circulante/genética , Receptores ErbB/genética , Frequência do Gene , Sequenciamento de Nucleotídeos em Larga Escala/métodos , Humanos , Neoplasias Pulmonares/diagnóstico , Neoplasias Pulmonares/genética , Neoplasias Pulmonares/patologia , Mutação , Proteínas Proto-Oncogênicas p21(ras)/genética
3.
Nat Med ; 26(12): 1852-1858, 2020 12.
Artigo em Inglês | MEDLINE | ID: mdl-33106665

RESUMO

Acute myeloid leukemia (AML) is the most common diagnosed leukemia. In older adults, AML confers an adverse outcome1,2. AML originates from a dominant mutation, then acquires collaborative transformative mutations leading to myeloid transformation and clinical/biological heterogeneity. Currently, AML treatment is initiated rapidly, precluding the ability to consider the mutational profile of a patient's leukemia for treatment decisions. Untreated patients with AML ≥ 60 years were prospectively enrolled on the ongoing Beat AML trial (ClinicalTrials.gov NCT03013998 ), which aims to provide cytogenetic and mutational data within 7 days (d) from sample receipt and before treatment selection, followed by treatment assignment to a sub-study based on the dominant clone. A total of 487 patients with suspected AML were enrolled; 395 were eligible. Median age was 72 years (range 60-92 years; 38% ≥75 years); 374 patients (94.7%) had genetic and cytogenetic analysis completed within 7 d and were centrally assigned to a Beat AML sub-study; 224 (56.7%) were enrolled on a Beat AML sub-study. The remaining 171 patients elected standard of care (SOC) (103), investigational therapy (28) or palliative care (40); 9 died before treatment assignment. Demographic, laboratory and molecular characteristics were not significantly different between patients on the Beat AML sub-studies and those receiving SOC (induction with cytarabine + daunorubicin (7 + 3 or equivalent) or hypomethylation agent). Thirty-day mortality was less frequent and overall survival was significantly longer for patients enrolled on the Beat AML sub-studies versus those who elected SOC. A precision medicine therapy strategy in AML is feasible within 7 d, allowing patients and physicians to rapidly incorporate genomic data into treatment decisions without increasing early death or adversely impacting overall survival.


Assuntos
Biomarcadores Tumorais/genética , Genômica , Leucemia Mieloide Aguda/tratamento farmacológico , Idoso , Idoso de 80 Anos ou mais , Anticorpos Monoclonais Humanizados/administração & dosagem , Anticorpos Monoclonais Humanizados/efeitos adversos , Protocolos de Quimioterapia Combinada Antineoplásica/efeitos adversos , Citarabina/administração & dosagem , Citarabina/efeitos adversos , Daunorrubicina/administração & dosagem , Daunorrubicina/efeitos adversos , Feminino , Humanos , Leucemia Mieloide Aguda/genética , Leucemia Mieloide Aguda/patologia , Masculino , Pessoa de Meia-Idade , Mutação/genética , Medicina de Precisão , Análise de Sobrevida , Resultado do Tratamento
4.
PLoS One ; 15(9): e0237802, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32976510

RESUMO

As availability of precision therapies expands, a well-validated circulating cell-free DNA (cfDNA)-based comprehensive genomic profiling assay has the potential to provide considerable value as a complement to tissue-based testing to ensure potentially life-extending therapies are administered to patients most likely to benefit. Additional data supporting the clinical validity of cfDNA-based testing is necessary to inform optimal use of these assays in the clinic. The FoundationOne®Liquid CDx assay is a pan-cancer cfDNA-based comprehensive genomic profiling assay that was recently approved by FDA. Validation studies included >7,500 tests and >30,000 unique variants across >300 genes and >30 cancer types. Clinical validity results across multiple tumor types are presented. Additionally, results demonstrated a 95% limit of detection of 0.40% variant allele fraction for select substitutions and insertions/deletions, 0.37% variant allele fraction for select rearrangements, 21.7% tumor fraction for copy number amplifications, and 30.4% TF for copy number losses. The limit of detection for microsatellite instability and blood tumor mutational burden were also determined. The false positive variant rate was 0.013% (approximately 1 in 8,000). Reproducibility of variant calling was 99.59%. In comparison with an orthogonal method, an overall positive percent agreement of 96.3% and negative percent agreement of >99.9% was observed. These study results demonstrate that FoundationOne Liquid CDx accurately and reproducibly detects the major types of genomic alterations in addition to complex biomarkers such as microsatellite instability, blood tumor mutational burden, and tumor fraction. Critically, clinical validity data is presented across multiple cancer types.


Assuntos
Bioensaio/métodos , Ácidos Nucleicos Livres/genética , Genômica , Neoplasias/genética , Classe I de Fosfatidilinositol 3-Quinases/genética , Receptores ErbB/genética , Éxons/genética , Humanos , Limite de Detecção , Mutação/genética , Intervalo Livre de Progressão , Reprodutibilidade dos Testes
5.
Blood ; 127(24): 3004-14, 2016 06 16.
Artigo em Inglês | MEDLINE | ID: mdl-26966091

RESUMO

The spectrum of somatic alterations in hematologic malignancies includes substitutions, insertions/deletions (indels), copy number alterations (CNAs), and a wide range of gene fusions; no current clinically available single assay captures the different types of alterations. We developed a novel next-generation sequencing-based assay to identify all classes of genomic alterations using archived formalin-fixed paraffin-embedded blood and bone marrow samples with high accuracy in a clinically relevant time frame, which is performed in our Clinical Laboratory Improvement Amendments-certified College of American Pathologists-accredited laboratory. Targeted capture of DNA/RNA and next-generation sequencing reliably identifies substitutions, indels, CNAs, and gene fusions, with similar accuracy to lower-throughput assays that focus on specific genes and types of genomic alterations. Profiling of 3696 samples identified recurrent somatic alterations that impact diagnosis, prognosis, and therapy selection. This comprehensive genomic profiling approach has proved effective in detecting all types of genomic alterations, including fusion transcripts, which increases the ability to identify clinically relevant genomic alterations with therapeutic relevance.


Assuntos
Impressões Digitais de DNA/métodos , Perfilação da Expressão Gênica/métodos , Genômica/métodos , Neoplasias Hematológicas/genética , Neoplasias Hematológicas/metabolismo , Aberrações Cromossômicas , Técnicas de Laboratório Clínico/métodos , Análise Mutacional de DNA/métodos , DNA de Neoplasias/análise , Regulação Neoplásica da Expressão Gênica , Neoplasias Hematológicas/patologia , Sequenciamento de Nucleotídeos em Larga Escala , Humanos , Mutação , Polimorfismo Genético , RNA Neoplásico/análise , Sensibilidade e Especificidade , Integração de Sistemas
6.
Immunohematology ; 30(3): 121-2, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-25695437

RESUMO

A novel RHCE allele was identified in a 53-year-old African American female blood donor with an Rh phenotype of D+ C­ E­ c+ e+ and a negative antibody screen. The donor's cells typed e+ with all antisera tested. By gel-based genotyping and cDNA analysis, the two RHCE alleles in this donor were characterized. One allele was found to be the known allele RHCE*01.20.01 (RHCE*ce733G) and the second was novel: RHCE*01.06.02 (RHCE*ce254G,733G).


Assuntos
Alelos , Sistema do Grupo Sanguíneo Rh-Hr/genética , DNA Complementar/genética , Feminino , Técnicas de Genotipagem , Humanos , Pessoa de Meia-Idade , Análise de Sequência de DNA
7.
Nat Biotechnol ; 31(11): 1023-31, 2013 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-24142049

RESUMO

As more clinically relevant cancer genes are identified, comprehensive diagnostic approaches are needed to match patients to therapies, raising the challenge of optimization and analytical validation of assays that interrogate millions of bases of cancer genomes altered by multiple mechanisms. Here we describe a test based on massively parallel DNA sequencing to characterize base substitutions, short insertions and deletions (indels), copy number alterations and selected fusions across 287 cancer-related genes from routine formalin-fixed and paraffin-embedded (FFPE) clinical specimens. We implemented a practical validation strategy with reference samples of pooled cell lines that model key determinants of accuracy, including mutant allele frequency, indel length and amplitude of copy change. Test sensitivity achieved was 95-99% across alteration types, with high specificity (positive predictive value >99%). We confirmed accuracy using 249 FFPE cancer specimens characterized by established assays. Application of the test to 2,221 clinical cases revealed clinically actionable alterations in 76% of tumors, three times the number of actionable alterations detected by current diagnostic tests.


Assuntos
Análise Mutacional de DNA/métodos , Técnicas de Diagnóstico Molecular/métodos , Neoplasias/genética , Análise de Sequência de DNA/métodos , Variações do Número de Cópias de DNA , Frequência do Gene , Humanos , Neoplasias/diagnóstico , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
8.
Transfusion ; 53(8): 1763-71, 2013 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-23145947

RESUMO

BACKGROUND: Although platelets (PLTs) are known to express ABH antigens, the extent of expression is different on PLTs compared with red blood cells and the relationship between PLT ABH expression and genotype has not been thoroughly investigated. STUDY DESIGN AND METHODS: We measured blood group H and A antigens on PLTs from 100 normal volunteers using fluorescent-conjugated reagents and flow cytometry. Individuals were also genotyped at the ABO locus using a commercially available genotyping system. RESULTS: Expression of A and H antigen varied widely on PLTs from different individuals. Among group A and AB persons, H antigen expression was significantly greater than A antigen (p < 0.0001). The ratio of H-to-A antigen expression varied more than 100-fold in a predictable fashion according to genotype with values lowest in A1/A1 < A1/O < A2/A2 < A2/O. H and A antigen expression was unaffected by secretor status. The proportion of PLTs with high A expression also varied directly according to genotype. CONCLUSIONS: Blood group A and H antigen expression on PLTs varies in a predictable fashion according to genotype. Flow cytometry and genotyping identify individuals who strongly express A antigens, a finding that may be relevant to clinical PLT transfusion across ABO barriers.


Assuntos
Sistema ABO de Grupos Sanguíneos/genética , Plaquetas/imunologia , Genótipo , Sistema ABO de Grupos Sanguíneos/metabolismo , Biomarcadores/sangue , Plaquetas/metabolismo , Citometria de Fluxo , Técnicas de Genotipagem , Humanos , Fenótipo
9.
Brain Behav Immun ; 23(2): 240-50, 2009 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-18938237

RESUMO

Morphine-induced glial proinflammatory responses have been documented to contribute to tolerance to opioid analgesia. Here, we examined whether drugs previously shown to suppress glial proinflammatory responses can alter other clinically relevant opioid effects; namely, withdrawal or acute analgesia. AV411 (ibudilast) and minocycline, drugs with distinct mechanisms of action that result in attenuation of glial proinflammatory responses, each reduced naloxone-precipitated withdrawal. Analysis of brain nuclei associated with opioid withdrawal revealed that morphine altered expression of glial activation markers, cytokines, chemokines, and a neurotrophic factor. AV411 attenuated many of these morphine-induced effects. AV411 also protected against spontaneous withdrawal-induced hyperactivity and weight loss recorded across a 12-day timecourse. Notably, in the spontaneous withdrawal study, AV411 treatment was delayed relative to the start of the morphine regimen so to also test whether AV411 could still be effective in the face of established morphine dependence, which it was. AV411 did not simply attenuate all opioid effects, as co-administering AV411 with morphine or oxycodone caused three-to-five-fold increases in acute analgesic potency, as revealed by leftward shifts in the analgesic dose response curves. Timecourse analyses revealed that plasma morphine levels were not altered by AV411, suggestive that potentiated analgesia was not simply due to prolongation of morphine exposure or increased plasma concentrations. These data support and extend similar potentiation of acute opioid analgesia by minocycline, again providing converging lines of evidence of glial involvement. Hence, suppression of glial proinflammatory responses can significantly reduce opioid withdrawal, while improving analgesia.


Assuntos
Analgesia/psicologia , Analgésicos Opioides/efeitos adversos , Encéfalo/metabolismo , Piridinas/farmacologia , Síndrome de Abstinência a Substâncias/fisiopatologia , Analgésicos Opioides/administração & dosagem , Analgésicos Opioides/farmacologia , Animais , Antibacterianos/administração & dosagem , Antibacterianos/farmacologia , Encéfalo/efeitos dos fármacos , Encéfalo/imunologia , Broncodilatadores/administração & dosagem , Broncodilatadores/farmacologia , Relação Dose-Resposta a Droga , Proteína Glial Fibrilar Ácida/metabolismo , Imuno-Histoquímica , Injeções Intraperitoneais , Masculino , Minociclina/administração & dosagem , Minociclina/farmacologia , Morfina/efeitos adversos , Naloxona/efeitos adversos , Transtornos Relacionados ao Uso de Opioides/etiologia , Transtornos Relacionados ao Uso de Opioides/metabolismo , Transtornos Relacionados ao Uso de Opioides/fisiopatologia , Transtornos Relacionados ao Uso de Opioides/psicologia , Oxicodona/efeitos adversos , Dor/fisiopatologia , Dor/psicologia , Medição da Dor , Piridinas/administração & dosagem , Ratos , Ratos Sprague-Dawley , Síndrome de Abstinência a Substâncias/etiologia , Síndrome de Abstinência a Substâncias/metabolismo , Redução de Peso/efeitos dos fármacos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...